KDC-M907
3
TEST MODE
·Panel open and closes with press long the [Q] key.
· No displays such as "CODE OFF" during Power-ON.
· Pressing the [TI (AUTO)] key during changer operation
turns on 2 zone. Cancel by pressing the [TI (AUTO)] key
again. The P/S dot is lit during 2 zone.
· Pressing the [4/8] key for 1 second or more during All
OFF, calls up the Mask Key (security) write mode.
Security Items
1. Forced power-ON mode (all models)
Even when writing is permitted by the security function
(mask key), Power-on can be set for a 30 minute period
each time the reset key is pressed while holding down the
[Q] key and [4/8] keys. After 30 minutes elapses, can only
be restored by using reset.
2. How to register the security code for EEPROM
(F/E) replacement (coded security models)
1) Enter the test mode. (See 1. How to enter the test mode)
2) Press the [4/8] key to enter the MENU MODE.
3) While "Security" is displayed, press and hold the [Track up
or down] key for a second to enter the secu-rity registration
mode.
4) Enter the code using the [FM/AM/Track up/Track down] keys.
FM key : Increments the number.
AM key : Decrements the number.
Track up key : Moves the cursor to the right.
Track down key : Moves the cursor to the left.
5) Hold down the [Track up] key for at least 3 seconds and the
message, "RE-ENTER" appears, so once again enter the
code according to Step 4) above.
6) Hold down the [Track up] key for at least 3 seconds, and
the message, "APPROVED" appears.
7) Cancel test mode. (See, 2. How to exit from the test mode.)
Note : All clear cannot be performed on the security code
for this model.
3. Simple way to clear the security code (K type only)
1) During code request mode, press the [Track up] key for at
least 3 seconds while holding down the [AUTO] key. (----
will disappear)
2) Enter, "KCAR" with the remote controller as described be-
low. (Same as on 01 model.)
· Press the remote controller [5] key twice, and press the
[Track up] key. (Enters a "K")
· Press the remote controller [2] key three times, and press
the [Track up] key. (Enters a "C")
· Press the remote controller [2] key once and press the
[Track up] key. (Enters an "A")
· Press the remote controller [7] key twice, and press the
[Track up] key. (Enters an "R")
3) Security function is canceled and unit sets to All-Off mode.
4) Code request mode appears if a mistake was made in en-
tering the numbers.
4. Method of writing the Mask key while the EEPROM is
in the initial status
1) Enter the test mode. (See 1. How to enter the test mode)
2) Press the [4/8] key to enter the Mask key registration mode.
"TRANSMIT1" should be displayed now. The display at this
time should show "< >" in place of "[ ]".
3) Point the Mask key remote toward the light sensor, and press
and hold its key for more than 0.5 second.
4) When "TRANSMIT2" is displayed, press and hold the key
on the Mask key remote for more than 0.5 second again.
The first and second counter codes are not compared at
this time.
5) When "APPROVED" is displayed, the write operation is com-
plete. Now the demonstration mode is initiated and the test
mode is terminated.
Note : In the same way as previous models, if 30 minutes
have elapsed with no code written, an error occurs and the
power is turned OFF.
5. Method of initializing the Mask key
(How to reset the unit from the Mask key approved con-
dition to the factory condition)
1) Enter the test mode. (See 1. How to enter the test mode)
2) "TRANSMIT1" is displayed and the Mask key entry request
mode is initiated. The display at this time should show ""
in place of "[ ]".
3) Press and hold the key on the Master key remote for more
than 3 seconds.
4) When "TRANSMIT2" is displayed, press and hold the key
on the Master key remote for more than 3 seconds again.
5) When "APPROVED" is displayed, the Mask key is cleared,
the demonstration mode is initiated, the test mode is termi-
nated and the unit returns to the factory condition.
6. Method of clearing all Mask key-related data
1) Enter the test mode. (See 1. How to enter the test mode)
2) Press the [4/8] key to enter the Mask key registration mode.
"TRANSMIT1" should be displayed now.
3) Point the Master key remote toward the light sensor, and
press and hold its key for more than 3 seconds (until the
level display shows the full condition).
4) When "TRANSMIT2" is displayed, hold the key on the Mask
key remote for more than 3 seconds again. If "TRANSMIT1"
is displayed in place of "TRANSMIT2", restart the proce-
dure from step 3).
5) When "APPROVED" is displayed, all security data is cleared
and the unit returns to the condition before Mask key writ-
ing with the EEPROM in the initial status.