3
DISPLAY UNIT (X14-6912-70)
Ref. No.
Application/Function
Operation /Condition/Compatibility
IC1
Stabilized power supply
Supplies Bu +5V to IC30, IC31, IC32, IC33, IC34, etc.
IC2
Stabilized power supply
Supplies D.+5V to X25 board
IC3
Stabilized power supply
Supplies +6.5V to mechanism X33
IC30
Reset IC
OUT=H when BU+5V is above 4.2V
IC31
1 pulse oscillation
Oscillates 1 pulse at rise of BU
IC32
NOT circuit
((~STATUS | | DIAG | | Sw to Pow) &&-LEV6) | | HOLD=H, then D.+5V ON
IC33
OR circuit
((~STATUS | | DIAG | | Sw to Pow) &&-LEV6) | | HOLD=H, then D.+5V ON
IC34
D flip-flop
Detects downward slope of J1 DIAG
Q1
Switch
Q1 base =L, then LEV16=12V
Q2
NOT circuit
Q2 base =H, then Q1 base =L
Q40
NOT circuit
J1 DIAG=L, then IC33 A3 input=H
Q41
NOT circuit
CN1 DIAGOUT=H, then J1 DIAG=L
Q42
Excess current protection
Limit Q41 emitter current
Q43
NOT circuit
J1 DIAG=L, then CN1 DIAGIN=H
Q60
Switch
CN2 LED1=H, then D60 lights up.
Q61
Switch
CN2 LED2=H, then D61 lights up.
Q62
Switch
CN2 LED3=H, then D62 lights up.
Q63
Switch
CN2 LED4=H, then D63 lights up.
Q64
Switch
CN2 LED5=H, then D64 lights up.
Q65
Switch
CN2 LED6=H, then D65 lights up.
Q66
Switch
CN2 LED6=H, then D66 lights up.
ELECTRIC UNIT (X25-9252-70)
Ref. No.
Application/Function
Operation /Condition/Compatibility
IC1
Stabilized power supply
Supplies 3.3V to IC30 and IC150.
IC30
µ-com
Controls various sections of the set.
IC70
D flip-flop
Detects rise of key input for LOAD/EJECT
IC71
NAND circuit
IC70 CLR=~ (IC90 RESET&&IC30 CLEAR)
IC90
RESET IC
D+5V is above 4.2V, then RESET=H.
IC91
EEPROM
Saves backup data.
IC150
DIR
Converts IEC60958 (SPDIF) signal to 3-line serial.
IC151
MOST transceiver
Signal processing IC for optical input/output
Q30
Switch
PF3=L, then AVREF ON.
Q70
NOT circuit
CN70 EJECT=H, then IC30 EJECT=L
Q71
NOT circuit
CN70 LOAD=H, then IC30 LOAD=L
Q180
NOT circuit
MOST ATT=H, then Q181 base=L
Q181
Switch
MOST ATT=H, then increase optical output.
COMPONENTS DESCRIPTION