KRC-108S/165/189 (REVISED)
2
SYNTHESIZER UNIT (X14-943/936)
Ref. No.
Application/Function
Operation/Condition/Compatibility
IC1
System
µ-com
System control
IC2
Electronic volume
Controls on volume and selection of various sources
IC3
Logic IC for muting
Mute control
IC4
POWER IC
Amplifier for speaker output
IC5
EQ AMP
Equalizer amp for the cassette player
IC6
RESET IC
IC for Power ON Reset
Q50
BU DET SW
"H" output when backup voltage is 9.2V or less
Q51,Q52
BU 5V Driver
Turned on when backup is turned ON.
Q53
P-ON5V SW
On while power is turned ON. (Except ALL-OFF)
Q54,Q55
8V SW
On while power is turned ON. (Except ALL-OFF)
Q56,Q57
8V Driver
On while power is turned ON. (Except ALL-OFF)
Q58,Q59
ILL+B SW
On while power is turned ON.
Q60,Q61
ILL+B Driver
On while power is turned ON.
Q62
ACC DET SW
"H" output when ACC is OFF.
Q63
ILL+B error prevention SW
Turned ON with "H" after
µ-com port is set.
Q150
Electronic volume MUTE SW
IC2 is muted when Back Up is detected or Reset and
µ-com mute is detected.
Q151
SVR forced discharge SW
When P-MUTE is ON (conditional), SVR discharge.
Q153,Q450,Q451
Pre Out MUTE SW
Pre Out is muted when back up is detected or Reset and
µ-com MUTE are detected.
Q200,Q201
FM+B SW
On in FM MODE
Q202,Q203
AM+B SW
On in AM MODE
Q260,Q261
MOT+B SW
On in TAPE MODE
Q301
RESET logic reverse SW
"H" output when RESET SW is ON.
Q350,Q353
P-CON Driver SW
Off when Power OFF and ALL OFF.
Q351
P-CON protection SW
On when P-CON shorts with GND.
Q352
P-CON protection prohibited SW
Protection switch is prohibited only at the moment when P-CON is turned ON.
Q354
P-CON error prevention SW
Turned ON with "H" after
µ-com port is set.
Q355
ANT-CON error prevention SW
Turned ON with "H" after
µ-com port is set.
Q370,Q371
ANT-CON Driver SW
When tuner is ON.
COMPONENTS DESCRIPTION
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
I/O
Application
Truth Value
Processing Operation Description
Table
1NC
-
2
VL1
I
Power source input for LCD
3~5
KI0~KI2
I
Key return input
6~9
KS0~KS3
O
Key scan output
10
TUN_SMETER
I
S-meter detection terminal
11
KS4
O
Key scan output
12
BEEP
O
Beep output
13
NC
O
Not used
14
MOTOR
O
Mechanism motor ON/OFF
H : Mechanism motor ON
15
FF/REW
I
Mechanism FF/RWD detection
L : FF/RWD detected for MUTE
16
PACKIN
I
Mechanism PACK-IN detected
TAPE IN : L, NO TAPE : H
17
KI3
I
Key return input
18
FWD/REV
I
Detection for mechanism playing direction
H : FWD, L : REV
19~25
NC
O
Not used
SYSTEM MICROCOMPUTER : M37560MFD904FP (X14 : IC1)