KRC-21SA/SG/SYA/SYG
KRC-266/S
3
q SYNTHESIZER UNIT (X16-149x-xx)
COMPONENTS DESCRIPTION
Ref.No.
Application/Functions
Operation/Condition/Compatibility
IC1
LCD driver with key-matrix
Q1
Key-matrix permission SW
Ready on key-matrix
q SYNTHESIZER UNIT (X14-685x-xx)
Ref.No.
Application/Functions
Operation/Condition/Compatibility
IC1
System MI-COM.
System control
IC2
E-VOL. & N.C. MPX
Controls sound volume. Selects each source.
IC3
Mute logic
3-input NOR gate x 3
IC4
Power IC
Amplifies power so that the speaker can drive audio signal.
IC5
Equalizer amplifier
Equalizer amplifier for cassette tape sound
Q50
BACK-UP detection(Momentary
power down detection) SW
While BACK-UP is added, a base becomes Hi, and Q50 is turned on.
Q51
BACK-UP 5V AVR
While BACK-UP is added, AVR outputs +5V.
Q52
Q51 and Q52 is inverted Darlington connection.
Q53
P.ON 5V SW
While a base becomes Lo, Q53 is turned on.
Q54
COM+B SW
While Q54's base becomes Hi, Q55 is turned on.
Q55
Works during POWER ON mode.
Q56
COM+B AVR
While Q57's base becomes Hi, Q56 is turned on.
Q57
Q56 and Q57 is inverted Darlington connection.
Q58
Illumination +B SW
While Q58's base becomes Hi, Q59 is turned on.
Q59
Works during POWER ON mode with a panel attached to the set.
Q60
Illumination +B AVR
While Q61's base becomes Hi, Q60 is turned on.
Q61
Q60 and Q61 is inverted Darlington connection.
Q150
Electric volume mute SW
When BACK-UP detection SW or CHANGER RESET SW or MI-COM.'s mute
works, a base becomes Hi, and Q150 is turned on.
Q151
SVR discharge SW
When POWER IC RESET is activated, a base becomes Hi, Q151 is turned on.
Q153
Pre-out mute driver
When BACK-UP detection SW or CHANGER RESET SW or MI-COM.'s mute
works, a base becomes Lo, and Q153 is turned on.
Q200
FM +B SW
Q201 is turned on when Q200's base becomes Hi.
Q201
Works during FM reception mode.
Q202
AM +B SW
Q203 is turned on when Q202's base becomes Hi.
Q203
Works during AM reception mode.
Q260
Motor +B SW
When Q260's base becomes Hi, Q261 is turned on. Works during TAPE mode.
Q261
Q301
Changer reset SW
When a base becomes Lo, Q301 is turned on.
Q320
Panel 5V SW
While a panel is attached to the set, a base becomes Lo, and Q320 is turned on.
Q350
P-CON. driver
When Q353's base becomes Hi, Q350 is turned on.
Q351
P-CON. protection SW
Works when P-CON is being short-circuited on GND.
Q352
P-CON. protection inhibit SW
Inhibits protection SW function when P-CON works momentary.
Q353
P-CON. SW
Q353 is turned on when a base becomes Hi. Works during POWER ON mode.
Q370
ANT-CON. SW
Q370 is turned on when Q371's base becomes Hi.Works during TUNER mode.
Q371
Q450
Pre-out mute SW (R ch.)
When BACK-UP detection SW or CHANGER RESET SW or MI-COM.'s mute
Q451
Pre-out mute SW (L ch.)
works, a base becomes Hi, and Q450,451 are turned on.