TK-260G/270G
5
OPERATING FEATURES
9) Reverse (REV) (Note: C type only)
When the REV switch is pressed, transmission can be
performed with the receive frequency and receive signaling,
and reception can be performed with the transmit frequency
and transmit signaling.
When REV is on, HORN ALERT and PUBLIC ADDRESS
do not work.
10) Selectable QT (SEL QT) (TK-270G M types only)
When the SEL QT switch is pressed, QT frequency can be
temporarily changed with the CH switch.
11) 2-Tone Encode Select (TK-270G only)
1 Press the key programmed as 2-tone Encode Select.
· A pre-programmed 2-tone code name appears on the
display.
2 Press the key programmed as Channel Up and Channel
Down to select you desired 2-tone code name.
3 Press PTT switch and 2-Tone Encode Select key to transmit
and release them to receive.
Note:
The code for the TK-260G is not selectable.
You cannot change the tone in step 2 by using the Channel
Up and Channel Down keys.
12) Redial (TK-270G only)
Pressing this key when Group/Channel is shown, displays
the previously transmitted DTMF code. Pressing [PTT] at
this time, transmits the code that is currently displayed.
13) RF power low
Used to temporarily switch transmission output to low power.
Turning the function on enables:
Hi
Low, LowLow
Key states are backed up, except in the PC mode when
they are reset.
14) Scan (TK-270G only)
Pressing this key starts scanning. Pressing this key again
stops scanning.
15) Scan Del/Add (TK-270G only)
This key switches the currently displayed channel between
"Delete" and "Add".
The "Add" channel is contained in the scan sequence, the
"Delete" channel is not contained. In the scan mode, this key
switches the channel between delete or add, temporarily.
16) Talk Around (TK-270G only)
Press this key, the transceiver uses the receive frequency
and tone for transmission.
The operator can call the other party directly (without
repeater). Press this key again, the talk around function
goes off.
17) None
An error operation beep sounds, and no action will occur.
Use this function when the transceiver is required to be
operated more simply.
3. Display (TK-270G only)
Icon
Description
Not used in this transceiver.
Appears when the selected channel is
busy.
Appears when QT, DQT, DTFM, or 2-
Tone decoding is deactivated (by
pressing the Monitor key).
Appears when you receive a Code
Squelch, Selective Call, 2-Tone, or
DTMF Signallling call. Also appears
when you transmit using Code Squelch
or Selective Call.
Appears while scanning.
Appears when using low power on the
selected channel.
Appears when the selected channel is
included in the scanning sequence.
Displays the selected channel, the
squelch level, DTMF digits (when
entering digits, confirming digits, or
making a call), and messages received
via Selective Call.
4. Scan Operating (TK-270G only)
1) Scan types
q
Single Group Scan
You can scan all valid (ADD) channels in the displayed group
that can be selected with the group selector.
q
Multiple Group Scan
You can scan all valid (ADD) channels in all valid (ADD)
groups.
2) Scan Start Condition
One or more non-priority channels must be added to all
channels that can be scanned. The transceiver must be in
normal receive mode (PTT off).
When you activate the key programmed to the scan function,
scan starts. The scan icon ("SCN") lights and "SCAN" is
indicated on display.