KRF-V8080D/V8080D-S/VR-8050
2
ACCESSORIES / CAUTIONS
FM indoor antenna (1)
(T90-0877-05): EE1
(T90-0905-05): KP
AM loop antenna (1)
(T90-0893-05)
Remote control unit (1)
RC-R0823
(A70-1623-05): EE1
RC-R0822
(A70-1622-05): KP
Batteries (R6/AA) (2)
Accessories
Model
Color
ABB.
KRF-V8080D
Black
E
KRF-V8080D-S
Silver
E1
VR-8050
Black
KP
Color vs Model
Resetting the Microcomputer
The microcomputer may malfunction (unit cannot be
operated, or shows an erroneous display) if the power
cord is unplugged while the power is ON, or due to
some other external factor. If this happens, execute the
following procedure to rese
· Please note that resetting the microcomputer will clear the
contents of the memory and return the unit to the state it
was in when it left the factory.
For the U.S.A. and Canada
Unplug the power cord from the wall outlet, then plug
it back in while holding down the POWER ON/STAND-
BY
key.
For other countries
With the power cord plugged in, turn the POWER
ON/OFF key OFF. Then, while holding down the
ON/STANDBY
key, press POWER ON/OFF key.
Cautions
· Power mode
· Input selector settings
· Picture output
· Speaker ON/OFF
· Volume level
· BASS, TREBLE, INPUT level
· TONE ON/OFF
· LOUDNESS ON/OFF
· Dimmer level
· MD/TAPE settings
· Listen mode setting
· Speaker settings
· Distance setting
· Input mode setting
·Sound mode settings
· Broadcast band
· Frequency setting
· Preset stations
· Tuning mode
· ACTIVE EQ mode
· SPEAKER EQ mode
Memory back up function
Please note that the following items will be deleted from the unit's
memory if the power cord is disconnected from the AC outlet for
approximately 1 day.