3
SERVICE SAFETY PRECAUTIONS
1. Replacing the fuses
CAUTION:
FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE OF
FUSE.
Reference Designator
Part Number
Description
F751*AH
33-0101001-00-48
FUSE 7A 250V TIME-LAG5 X 20mm
SIC UL/CSA
F751*C
33-0141002-00-48
FUSE 4A 250V TIME-LAG 5 X 20mm
VDE/UL TSD
F752*AH
33-0111006-00-48
FUSE 1.6A 250V TIME LAG LBC 5x20mm
TSD UL/CSA/VDE/SEMKO
F752*C
33-0151006-00-48
FUSE 800mA 250V TIME LAG LBC 5x20mm
TSD UL/CSA/VDE/SEMKO
FH751-FH752
33-1000000-00-88
FUSE CLIP 0.05mm FC-53-11
NOTE: <*AH > : USA, CANADIAN MODEL ONLY.
<*C >
: EUROPEAN MODEL ONLY.
2. Safety check out
(Only U.S.A. model)
Before returning the product to the customer, make leakage current or resistance measurements to determine
that exposed parts are acceptably insulated from supply circuit.
CONTENTS
DESCRIPTION
PAGE
SPECIFICATIONS ............................................................................................................................ 4 - 5
REAR PANEL / FRONT PANEL VIEW .................................................................................................. 6
DISASSEMBLY INSTRUCTIONS .......................................................................................................... 7
WIRING DIAGRAM ................................................................................................................................ 8
BLOCK DIAGRAM ................................................................................................................................. 9
SPECIAL FUNCTION .......................................................................................................................... 10
DETAILS & WAVEFORMS ON SYSTEM & TEST & DEBUGGING .................................................... 10
ADJUSTMENT POINTS DIAGRAM / AMPLIFIER ADJUSTMENT ....................................................... 11
PCB LAYOUT ............................................................................................................................... 12 - 23
SCHEMATIC DIAGRAM ............................................................................................................... 24 - 40
IC BLOCK DIAGRAM ................................................................................................................... 41 - 46
EXPLODED VIEW ............................................................................................................................... 47
EXPLODED VIEW PARTS LIST ................................................................................................... 48 - 49
ELECTRICAL PARTS LIST .......................................................................................................... 50 - 62
PACKING DIAGRAM .......................................................................................................................... 63
VERSION HISTORY .......................................................................................................................... 64
Parts marked with the symbol
are critical with regard to the risk of fire and electric shock.
Replace only with parts recommended by the manufacturer.