SKW-100
SPECIFICATION
1. Replacing the fuse
This symbol located near the fuses indicates that the
fuse used is fast operating type. For continued protection against
fire hazard, replace with same type fuse. For fuse rating refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utlise est a rapide.
Pour une protection permanente, n'untiliser que fusibles de
meme type. Ce darnier est la qu le present symbol est
appse.
CIRCUIT NO.
PART NO.
DESCRIPTION
F902,903
HWF1180406100
T4AL/250V, Fuse
SERVICE PROCEDURES
Type
Bass-reflex with built-in power amplifier
Frequency response
30 Hz-150 Hz
Output power
150 W Dynamic
Input sensitivity
220 mV
Input impedance
15 k
Woofer
8 inch cone type
Power supply
AC120V, 60Hz
Power consumption
75 W
Dimensions (WxHxD)
9-1/4" x 20-5/16" x 16-3/16" / 235 x 516 x 411 mm
Weight
29.1 lbs. / 13.2 kg
Specifications and appearance may subject to change for improvement without prior notice.