SERVICE PROCEDURE-1
T-4555/4555P
V.1.02/06823A-3
Clear
---> STANDBY
!
!
!
!
!
!
1. Replacing the fuse
REF. NO.
F901
F901 or
F901
F901 or
F901
F901 or
PART NAME
FUSE
FUSE
FUSE
FUSE
FUSE
FUSE
DESCRIPTION
1.25A-UL/T-233
1.25A-T/UL-ST2
1.25A-SE-EAWK FUSE
1.25A-SE-TL250V
1.25A-SE-EAWK FUSE
1.25A-SE-TL250V
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse , For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
PART NO. (SN)
252318GR
252251GR
252071GR
252272GR
252071GR
252272GR
3. Check the version of microprocessor
(1) Connect the AC power cord into a wall outlet.
(2) Press the STANDBY/ON button to turn on the unit.
(3) Press and hold down the DISPLAY button, then press the STANDBY/ON button.
(4) Press the STANDBY/ON button to turn off the unit.
(5) Disconnect the AC power cord from a wall outlet.
version
3 seconds
FL display
REMARKS
P<MDD>
P<MDD>
<MPP>
<MPP>
<MPB>
<MPB>
2. Initialize the unit
(1) Connect the AC power cord into a wall outlet.
(2) Press the STANDBY/ON button to turn on the unit.
(3) Press and hold down the MEMORY button, then press the STANDBY/ON button.
(4) Disconnect the AC power cord from a wall outlet.
FL display