TX-SR804/804E
SERVICE PROCEDURE
1. Replacing the fuses
This symbol located near the fuse indicates that the
fuse used is show operating type, For continued protection against
fire hazard, replace with same type fuse, For fuse rating, refer to
the marking adjacent to the symbol.
Ce symbole indique que le fusible utilise est e lent.
Pour une protection permanente, n'utiliser que des fusibles de meme
type. Ce demier est indique la qu le present symbol est apposre.
2. To initialize the unit
This model uses a battery-less memory backup system in order to retain radio presets and other settings
when it's unplugged or in the case of a power failure.
Although no batteries are required, the unit must be plugged into an AC outlet in order to charge the
backup system. Once it has been charged, the unit will retain the settings for several weeks,
although this depends on the environment and will be shorter in humid climates.
1. Press and hold down VIDEO 1 button, then press STANDBY/ON button when the unit is Power on.
2. After " Clear " is displayed, the preset memory and each mode stored in the memory are initialized and will
return to the factory settings, and turn to Standby mode.
4. Memory Backup
3. Safety check out
REF NO.
PART NAME
DESCRIPTION
PART NO.
REMARKS
F901
FUSE
10A-UL/T-233
252330GR
!, <DC>
F902
FUSE
6.3A-SE-EAK
252079GR
!, <WT>
F951
FUSE
6.3A-SE-EAK
252079GR
!
F952
FUSE
6.3A-SE-EAK
252079GR
!
F6901
FUSE
12A-TUL-250V
252301GR
!
F6902
FUSE
12A-TUL-250V
252301GR
!
<Notes>
<GK>
: TX-SR804 Korean model
<GQ>
: TX-SR804 Hong kong model
<GR>
: TX-SR804 Chinese model
<PA>
: TX-SR804 Australian model
<WT> : TX-SR804 World wide model
<PP>
: TX-SR804E European model
<DC>
: TX-SR804 Canadian model
F901
FUSE
6.3A-SE-EAK
252079GR
!, <WT,GQ,GR,GK,PA,PP>
F903
FUSE
2.5A-SE-EAK
252075GR
!, <WT,GQ,GR,GK,PA,PP>
F903
FUSE
5A-UL/T-233
252326GR
!, <DC>
F931
FUSE
1.6A-SE-EAK
252073GR
!
F932
FUSE
1.6A-SE-EAK
252073GR
!
(U.S.A. model only)
After correcting the original service problem, perform the following safety check before releasing the unit to
the customer.
.
Leakage current Check
Measure the leakage current to a known earth ground (water pipe or conduct etc.) by connecting a leakage current
tester between the earth ground and exposed metal parts of the unit (input/output ground terminals, screw heads or
metal overlays etc.).
Plug the power supply cord directly into a 120Vac 60Hz wall socket and turn STANDBY button on.
Any current measured must not exceed 0.5mA.